Chapter 5: Subsystem Maintenance and Upgrading
Replacing Controller Module Components
5-3
5.2. Replacing Controller Module Components
5.2.1 Overview
The controller module should never be removed unless the following replaceable
components need to be accessed:
DIMM Module: The DIMM module must be replaced when the DIMM
module fails or if a larger capacity DIMM module is
required.
Controller Module itself: If the controller module in a single-controller
configuration fails, it is necessary to power the system
down and replace the controller.
If a DIMM module or RAID controller fails, contact you vendor immediately for a
replacement. To replace any of these components, the controller module must first be
removed from the subsystem.
5.2.2 Notes on Controller Module Maintenance
The controller module contains a DIMM module. It is not recommended to re-use
the DIMM module extracted from a failed controller unless you have a similar RAID
subsystem that can be used to test the module.
We provide a three-year warranty for subsystem components. You can contact your
vendor for sending the failed controller in for repair.
When replacing the controller module, you must remember that the controller board
is one of the most sensitive components in the subsystem. All previously stipulated
safety precautions (see Chapter 2) must be strictly adhered to. Failure to adhere to
these precautions can result in permanent damage to the controller board, resulting in
timely delays.
For your own safety and that of the subsystem, make sure that no power is being
supplied to the system prior to replacing the controller module.